Description: Mixed Signal Oscilloscope 4 analog + 16 digital channels
Manufacturer | Tektronix Inc |
---|---|
Series | MSO70000 |
Part Number | MSO70604C |
Need to purchase this item?
Tektronix MSO70604C Oscilloscope
The Tektronix MSO70604C Oscilloscope has 6 GHz of Simple Bandwidth, 25 GS/s Simple Sample Rate 4 Channels, and 31 MS of Standard Memory.
Model MSO70604C waveform cursors make it simple to quantify follow to-follow timing qualities, while cursors that connection amongst YT and XY display modes make it simple to research stage connections and Safe Operating Area infringement. You will be able to select from 53 programmed estimations utilizing a graphical palette that intelligently arranges estimations into Amplitude, Time, Histogram, and Communications classes. Characterize and apply math articulations to waveform information for on-screen, brings about terms that you can utilize, you can access normal waveform math capacities. Or, on the other hand, for cutting edge applications, make mathematical articulations comprising of live waveforms, reference waveforms, math capacities, estimation esteems, scalars, and client movable factors with a simple to-utilize number cruncher style proofreader.
With profound securing memory, the MSO70604C testing should be possible over many cycles and long length inclines in the information can be watched. Furthermore, information from the oscilloscope can be transferred into Microsoft Excel utilizing the Excel toolbar, and it can be organized into custom reports utilizing the Word toolbar furnished with the MSO/DPO70000 Series.
The manual for this model can be found on the
Model | MSO70604C |
---|---|
Manufacturer | Tektronix |
Series | MSO70000 |
Type | Oscilloscope |
Sample Rate | Up to 25 GS/s |
Bandwidth | 6 GHz |
Channels | 4 analog and 16 digital channels. |
Waveform Capture Rate | >300,000 wfms/s max per channel |
Status | One Year |
MSO70604C Manual | User Manual and Maintenance Manual Available for Download |
Application | Industrial |
website.
MSO70604C FAQ- Tektronix Oscilloscope
Frequently Asked Questions
Question:
What is the jitter noise floor for the MSO70604C with BWE enabled?
Answer:
For the MSO70604C, the jitter noise floor with BWE enabled is 300 fs.
Question:
What types of acquisition modes does the MSO70604C have?
Answer:
The acquisition modes include, but are not limited to: sample, average, envelope, hi-res, peak detect, FastAcq, FastFrame, roll mode, and waveform database.
Question:
How many waveform measurements are there on the MSO70604C?
Answer:
This model has 53 automatic measurements.
Question:
What is the typical signal-to-noise ratio for the MSO70604C?
Answer:
The typical signal-to-noise ratio for the MSO70604C is 34 dB.